L'UDC 1-3kVA est un UPS de nouvelle génération de petite puissance de KSTAR, les entrées et sorties sont monophasées, le facteur de sortie est de 0,8.L'efficacité de cet UPS est très élevée, il peut réaliser des économies d'énergie et réduire le coût du client en conséquence.

4300DH 4081DH

Description

Capacity (VA/W): 2000va/1800W


Input

Rated Voltage: 100/110/115/120/127VAC or 200/208/220/230/240VAC
Frequency Range: Voltage Range: 55-145VAC or 110-300VAC
Frequency Range: 40Hz-70Hz(auto detect)
Power Factor: >= 0.99

Bypass Voltage Range:

Bypass high voltage point:
For 200/208/220/230/240 VAC models: 230-264: setting the high voltage point in LCD from 230VAC to 264VAC (default 64VAC)
For 100/110/115/120/127 VAC models: 115-132:setting the high voltage point in parameter 3 from 115 VAC to 132VAC (default: 132 VAC)

Bypass low voltage point:
For 200/208/220/230/240 VAC models: 170-220: Setting the low voltage point in parameter 3 from 95 VAC to 110 VAC (default:95VAC)
For 100/110/115/120/127/VAC models:95-110: setting the low voltage point in parameter 3 from 95VAC to 110 VAC. (default:95VAC)

ECO Range: Same as bypass
Generator input: Support

Output

Phase: Single phase & Ground
Rated Voltage: 100/110/115/120/127VAC or 200/208/220/230/240VAC
Power Factor: 0.9
Voltage Regulation: +/- 1%

Frequency:
Utility Mode: 47-53Hz (for 50Hz) or 57-63Hz (for 60Hz)
Battery Mode: 50/60Hz+/- 0.01Hz

Crest Factor: 3:1
THDv: <= 3% with linear load, <=6% with non linear load

Waveform: Pure Sinewave

Efficiency

ACMode (full load): >89%

Battery

Voltage: 48Vdc
Quantity: 4pc
Capacity(standard Unit): N/A
Backup: Long run unit depends on the capacity of external batteries
Recharge time to 90%: 4 hours
Charging Current (Built-in/Max.): 1A

Transfer Time

Utility to Battery: 0ms; Utility to bypass: <4ms

Prtection

Overload:
AC Mode: Ambient Temp.<35°C
-- 105%-110%: UPS shuts down after 10 minutes at battery mode or transfer to bypass when the utility is normal
-- 110%-130%: UPS shuts down after 1 minutes at battery mode or transfer to bypass when the utility is normal
-- >130%: UPS shuts down after 3 seconds at battery mode or transfer to bypass when the utility is normal

Bat.Mode 35°C < Ambient Temp.<40°C
-- 105%-110%:UPS shuts down after 1 minutes at battery mode or transfer to bypass when the utility is normal
-- >110%:UPS shuts down after 3 seconds at battery mode or transfer to bypass when the utility is normal

Bypass Mode:
-- 16A(input breaker)

Short circuit: Hold whole system
Overheat: Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately
Battery Low: Alarm and Switch off
EPO(optional): Shut down UPS immediately
Battery: Advanced battery Managment

Alarms

Audible & Visual: Line Failure, Battery low, Overload, System Fault

Display

Status LCD: Line Mode, Backup Mode, Eco Mode, Bypass Low, Battery Bad, Oberload & UPS Fault
Reading On the LCD: Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage

Physical

Dimension (WxHxD)mm: 144x209x399
Weight (kg): 6.8


Communication Interface

Communication Port: RS232 or USB
communication Slot: SNMP Card, Relay card,etc.

Environment

Operation Temperature: 0°C-40°CC
Storage Temperature: -25°C-+55°C
Humidity: 20-90% non condensing
Altitude: <1500m (derating while >1500m)
Noise: <50dB( at 1 meter)

Safety Conformance:

IEC/EN62040-1-1, IEC/EN62040-2