ONDULEUR KSTAR 3KVA/2.7KW On-line Smart UPS (KS-UDC9103S)
Add to Wishlist
4800DH
4656DH
Description
Capacity (VA/W): 3000va/2700W
Input
Rated Voltage: 100/110/115/120/127VAC or 200/208/220/230/240VACFrequency Range: Voltage Range: 55-145VAC or 110-300VAC
Frequency Range: 40Hz-70Hz(auto detect)
Power Factor: >= 0.99
Bypass Voltage Range:
Bypass high voltage point:For 200/208/220/230/240 VAC models: 230-264: setting the high voltage point in LCD from 230VAC to 264VAC (default 64VAC)
For 100/110/115/120/127 VAC models: 115-132:setting the high voltage point in parameter 3 from 115 VAC to 132VAC (default: 132 VAC)
Bypass low voltage point:
For 200/208/220/230/240 VAC models: 170-220: Setting the low voltage point in parameter 3 from 95 VAC to 110 VAC (default:95VAC)
For 100/110/115/120/127/VAC models:95-110: setting the low voltage point in parameter 3 from 95VAC to 110 VAC. (default:95VAC)
ECO Range: Same as bypass
Generator input: Support
Output
Phase: Single phase & GroundRated Voltage: 100/110/115/120/127VAC or 200/208/220/230/240VAC
Power Factor: 0.9
Voltage Regulation: +/- 1%
Frequency:
Utility Mode: 47-53Hz (for 50Hz) or 57-63Hz (for 60Hz)
Battery Mode: 50/60Hz+/- 0.01Hz
Crest Factor: 3:1
THDv: <= 3% with linear load, <=6% with non linear load
Waveform: Pure Sinewave
Efficiency
ACMode (full load): >89%Battery
Voltage: 48VdcQuantity: 4pc
Capacity(standard Unit): N/A
Backup: Long run unit depends on the capacity of external batteries
Recharge time to 90%: 4 hours
Charging Current (Built-in/Max.): 1A
Transfer Time
Utility to Battery: 0ms; Utility to bypass: <4msPrtection
Overload:AC Mode: Ambient Temp.<35°C
-- 105%-110%: UPS shuts down after 10 minutes at battery mode or transfer to bypass when the utility is normal
-- 110%-130%: UPS shuts down after 1 minutes at battery mode or transfer to bypass when the utility is normal
-- >130%: UPS shuts down after 3 seconds at battery mode or transfer to bypass when the utility is normal
Bat.Mode 35°C < Ambient Temp.<40°C
-- 105%-110%:UPS shuts down after 1 minutes at battery mode or transfer to bypass when the utility is normal
-- >110%:UPS shuts down after 3 seconds at battery mode or transfer to bypass when the utility is normal
Bypass Mode:
-- 20A(input breaker)
Short circuit: Hold whole system
Overheat: Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately
Battery Low: Alarm and Switch off
EPO(optional): Shut down UPS immediately
Battery: Advanced battery Managment
Alarms
Audible & Visual: Line Failure, Battery low, Overload, System FaultDisplay
Status LCD: Line Mode, Backup Mode, Eco Mode, Bypass Low, Battery Bad, Oberload & UPS FaultReading On the LCD: Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage
Physical
Dimension (WxHxD)mm: 144x209x399Weight (kg): 27.6
Communication Interface
Communication Port: RS232 or USBcommunication Slot: SNMP Card, Relay card,etc.
Environment
Operation Temperature: 0°C-40°CCStorage Temperature: -25°C-+55°C
Humidity: 20-90% non condensing
Altitude: <1500m (derating while >1500m)
Noise: <50dB( at 1 meter)
Safety Conformance:
IEC/EN62040-1-1, IEC/EN62040-2General
Brand | |
---|---|
Label |
Technical Specs
Screen Size | 40″ |
---|---|
Aspect Ratio | 16:9 |
3DTV | No |
Recommended Resolution | 1080p |
Panel | LED |
Tuner | ATSC/Clear QAM Tuners |
Refresh Rate | 120Hz |
Refresh Rate | 120Hz |
Connectivity
HDMI | 2 In | ||
---|---|---|---|
Digital Audio | 1 Optical Out | ||
Other Connectors | 1 x RF In | 1 x Audio Out (Mini Jack) | 1 x RS232C |
LAN | 1 | ||
Composite A/V | 1 In | ||
USB | 2 | ||
Component Video | 1 in |
first last –
Wow great product